Endress+Hauser
Promass 83E
Promass 83E Coriolis flowmeter

Detail

Produced by Endress+Hauser
Product headline

The flowmeter for minimized cost of ownership

with extended transmitter functionality.

Highly accurate measurement of liquids and gases for

a wide range of standard applications.

Sensor features

Cost‐effective – multi‐purpose device;

an alternative to conventional volumetric flowmeters.

Fewer process measuring points –

multivariable measurement (flow, density, temperature).

Space‐saving installation – no in/outlet run needs.

Compact dual‐tube system.

Medium temperature up to +140 °C (+284 °F).

Transmitter features

Quality – software for filling & dosing,

density & concentration, advanced diagnostics.

Flexible data transfer options – numerous communication types.

Automatic recovery of data for servicing.

4‐line backlit display with touch control.

Device in compact or remote version.

Nominal diameter range DN 8 to 80 (⅜ to 3")
Wetted materials Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Measured variables

Mass flow, density, temperature, volume flow,

corrected volume flow, reference density

Max. measured error Mass flow (liquid): ±0.15 % (standard), 0.1 % (option)
Volume flow (liquid): ±0.2 %
Mass flow (gas): ±0.75 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 180 000 kg/h (0 to 6600 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range –40 to +140 °C (–40 to +284 °F)
Ambient temperature range Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
Degree of protection IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation 4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Outputs 4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay
Inputs 2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive)
Digital communication HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP
Power supply DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals ATEX, IECEx, FM, CSA, NEPSI, TIIS
Other approvals and certificates

3.1 material, calibration performed on accredited calibration facilities

(acc. to ISO/IEC 17025), NAMUR, SIL, marine
PED, CRN
3A

 

Related Products