Product Category
News
Visitor
Online:2
Visitors:850313
Rotronic
HF562-WB7XDHXX
HF5-series
Humidity and temperature measurement
Detail
Technical data:
Produced by | Rotronic |
---|---|
Dimensions |
HF52, HF53, HF54, HF55: 129 x 72 x 45 mm HF56: 192 x 102 x 52 mm |
Weight | 220 g / 500 g |
Operating range electronics |
HF520: -25…60 °C / 0…100 %rh / HF53/54/55/56: -40…60 °c / 0…100 %rh / HF5X with screen -10…60 °C |
Accuracy at 23 ±5 °C | Probe dependent |
Power supply / Power consumption | 15…40 VDC or 12…28 VAC/ <100 mA |
Psychrometric calculations | All psychrometric values |
Number of probe inputs | 1 |
Initialisation time | Typically <3 sec. |
Display type | Optional graphics display. Presentation configurable. |
Backlight | with Backlight |
Alerting | Sensor break or short circuit, programmable. |
Alarm indicators | Yes |
Exploitation software | ROTRONIC HW4.2 |
Probe adjustment by software | Yes, with service cable |
Probe adjustment by keypad | display / keyboard |
Firmware update | With internet and HW4 software |
Data processing via HW4 | Graphics, statistics, analysis, qualification, etc. |
Circuit type | 2 -Wire or 3/4-Wire |
Analogue outputs scaleable by the user | Yes |
Analog output signal (standard) | 2 x 0…1 V, 0…5 V, 0…10 V, 0(4)…20 mA |
Automatic load compensation | Yes |
Communication interfaces | RS-458 / USB / LAN / WLAN / PoE (Modus B) |
Service Interface | Mini USB (UART) |
Enclosure material | ABS / Aluminium (HF5xxS) |
Cable connections | M16 cable gland and screw terminals |
IP protection rating | IP65 / Corresponds to UL94-HB protection class |
FDA/GAMP compatibility | FDA 21 CFR Part 11 and GAMP compatible |